Boreal Laser

Boreal Laser develops, manufactures, and sells Laser Based Gas Detection Products for both industrial leak detection, ambient monitoring, or process monitoring/control applications all around the world through a network of highly technical distributors. Boreal Laser products are ideal for variety of industrial applications including Leak Detection, Ambient Monitoring and Process Monitoring or Control. Boreal Laser products are widely adopted in 47 countries in industrial applications primarily for its large area coverage, fast speed of response, and maintenance friendly operation.

Request Info

Overview

Industries

Field Services

Vector can help schedule you for routine maintenance, installation, start up, commissioning, training and inspections.

Training

Vector University offers courses on all products to keep your processes running safely, optimally and cost effectively.

Laser Gas Detection

Open Path (OPX) Head Assembly

Open Path (OPX) Head

Open Path (OPX) Head

The Open Path (OPX) Head Assembly consists of Open Path (OPX) Measurement Head, Retro-Reflector, and Cable Kit. When the Open Path (OPX) Head Assembly is combined with the GasFinder3-DC, it creates an Open-Path Gas Detector that uses laser light to detect specific target gas molecules.

Open Path Laser Gas Detectors are used primarily for these applications:

  • Leak Detection – provides immediate and unambiguous detection of fugitive gas releases in industrial safety applications.
  • Ambient Monitoring – Continuously monitor gas concentrations accurately and reliably over open area and/or point sources for environmental monitoring applications.

This technology is ideal for detecting or monitoring for several different Toxic, Combustible, Hazardous, or Greenhouse Gases. The most popular gases include: Hydrogen Sulfide/Sulphide (H2S), Ammonia (NH3), Hydrogen Fluoride (HF), Methane (CH4), Carbon Monoxide (CO), and Carbon Dioxide (CO2).

Request Quote

Remote Point (RPX) Probe Assembly

Remote Point (RPX) Probe

Remote Point (RPX) Probe

The RPX Probe is a measurement head for GasFinder3-DC analyzers that provides a path average concentration in the 0.5m active measurement path (ambient atmosphere). The RPX Probe can be used with the GasFinder3-DC in Hazardous Area: Class 1, Zone 1, IIC (Groups A,B,C,D).

The analyzer can be mounted locally or remotely up-to a maximum of 100m cable length. Fiber optic cable carries the laser light from the GasFinder3-DC to the remotely mounted stack/duct probe (Transceiver). The active measurement path is formed by the laser light passing through the stack/duct and being returned by a retroreflector mounted on the opposite side of the duct. The laser light is then collected on a photodiode and the signal is carried back to the analyzer via CAT6 cable.

Request Quote

Stack/Duct (SDX) Probe Assembly

Stack Duct (SDX) Probe

Stack Duct (SDX) Probe

The Stack/Duct (SDX) Probe enables GasFinder3-DC analyzers to monitor the path average concentration inside a stack or duct with typical path lengths of 0.5 to 20m.

The analyzer can be mounted locally or remotely up-to a maximum of 100m cable length. Fiber optic cable carries the laser light from the GasFinder3-DC to the remotely mounted stack/duct probe (Transceiver). The active measurement path is formed by the laser light passing through the stack/duct and being returned by a retroreflector mounted on the opposite side of the duct. The laser light is then collected on a photodiode and the signal is carried back to the analyzer via CAT6 cable.

Request Quote

Response Cell

Extractive Measurement (EMX) Cell

Extractive Measurement (EMX) Cell

This is typically used in leak detection installations where the target gas is not normally present in the ambient atmosphere. Response cells are used for quality assurance purposes to validate that the GasFinder instrument is responding appropriately to a nominal concentration of the target gas. HF Response Cells are not currently available in this configuration.

Request Quote

In-Line Response Cell

In-Line (ILX) Probe

In-Line (ILX) Probe

This product is typically used in leak detection installations where the Measurement Head might be difficult to access. Response cells are used for quality assurance purposes to validate that the GasFinder instrument is responding appropriately to a nominal concentration of the target gas.

Request Quote

Alignment Kit

The Alignment Kit is used for the installation, commissioning, and alignment of primarily the OPX and SDC Measurement Heads. The Alignment Kit is a useful accessory for OPX and SDX Heads but it is strongly encouraged for OPX Head applications path lengths beyond 100m.

Request Quote

GasFinder3-OP

The GasFinder3-OP is a field deployable Open-Path Tunable Diode Laser (OP-TDL) based gas analyzer system that is primarily used for:

  • Leak Detection – provides immediate and unambiguous detection of fugitive gas releases in industrial safety applications
  • Ambient Monitoring – Continuously monitors gas concentrations over open area and/or point sources for environmental monitoring applications

This technology is also most referred to as Open Path Gas Detection (OPGD) or Line of Sight (LOS). This technology is ideal for detecting or monitoring for several different Toxic, Combustible, Hazardous, or Greenhouse Gases.

Request Quote

GasFinder2-VB

Boreal has provided gas detection solutions to land-based vehicles for the last 18 years. The GasFinder2-VB analyzer combines GPS location data to give highly accurate positioning for fugitive emission leaks. The live read-out display and alarm provide the operator with instantaneous gas concentration data.

What it does:

  • Provides immediate and unambiguous detection of the target gas in the ambient atmosphere
  • Our technology counts every target molecule in the measurement path to give a ppm concentration
  • The system combines the ppm concentrations, GPS coordinates, and associated diagnostic data for intuitive data interpretation
Request Quote

GasFinder2-AB

Boreal has been the industry leader in airborne gas detection systems for the last 16 years. The analyzer combines GPS location data to give highly accurate positioning for fugitive emission leaks. The live read-out display and alarm provide the operator with instantaneous gas concentration data.

What it does:

  • Provides immediate and unambiguous detection of the target gas in the ambient atmosphere
  • Our technology counts every target molecule in the measurement path to give a ppm concentration
  • The system combines the ppm concentrations, GPS coordinates, and associated diagnostic data for intuitive data interpretation
Request Quote

LET’S WORK TOGETHER

Vector Controls and Automation Group is a leading manufacturing representative, distributor, and valued partner for your application solution. We have partnered with the top manufacturing brands in the industry to offer complete, turnkey solutions to the marketplace.

CONTACT US