Industry Segments

  • Refining

  • Chemical

  • Power

Vector’s Continuous Emissions Monitoring System (CEMS) is the complete solution to comply with EPA requirements. At our Pearland campus, the engineered package is designed and integrated to meet regulatory permits.

Vector CAG CEMS Solutions Flyer

CEMS Solutions

Why Vector CAG

Cool-Dry Extractive Systems

  • Sample gas is extracted and conditioned to remove moisture prior to analysis
  • Conditioning at the CEM shelter
  • Heated sample line is required to keep the wet sample above its dew point until it reaches the moisture removal system

Hot-Wet Extractive Systems

  • No moisture removal – Moisture remains in the system throughout the sampling and measurement process
  • Sampling line, pump, and analytical equipment are heated to ensure the wet sample is analyzed hot, and gas is wet

Points to Consider

  • Temperature of the sample
  • Moisture content in the sample
  • Dew point of sample gas
  • Particulate content in the stack
  • Corrosive components in the sample
  • Range of the analyzer
  • Area classification, (safe area or class 1 div 2)
  • Maintenance requirement of the analyzer
CEMS Solutions

Calibration

Calibration of an analyzer ensures that the analyzer is reading the certified gas correctly. Calibration gas sent to the probe and back to ensure no bias in sample system.

Testing

  • 7 day drift prior to going live
  • Daily validation
  • Quarterly CGA
  • Yearly RATA

Our Manufacturers

LET’S WORK TOGETHER

Vector Controls and Automation Group is a leading manufacturing representative, distributor, and valued partner for your application solution. We have partnered with the top manufacturing brands in the industry to offer complete, turnkey solutions to the marketplace.